For diagram ( a)the reflection of light
bulb will be absorb
by the window, no much light to spread
for security purposes.
Now I will discuss step by household wring let start with
bedroom, For bedroom you can fix wall bracket, may be with recess on ceiling it can be one or two ceiling fan, 15a
socket outlet need to reduce depend on the 13a socket out lent need to reduce, depend
on the need of the household. but as electrician you can give advice for proper
electrification remember safety came first .
When you observed, in the above plan A ,there is garage
where car can be park, in the case of garage may be only light can be fixed ,if
there is safety you can fixed 13A socket outlet at entering door there is
condor it need lighting point sometime it need one light point or more than
depend on the length .you can loop 13A socket outlet, those that
feed small load at the dining room you can fix change
layer for customizing the dining room ,in the kitchen, you can know more illumination
required just like day light which allow
sanitation during cooking to be observe.Cooker control unit also will be installed inside kitchen for cooking food.
In the case of bathroom, water heater can be fixed, but its
switch is at the outside on the wall (side of the door) all the switches for
lighting in the toilet must mounted at outside of the toilet door because,
moisture lead to the electric shock that is the reason we position the
switches outside the toilet by looking the above plan a, as electrician
what you need to carryout household
electrical wiring?
ACCESSORIES:
ü
Couple-rs
ü
P.V.C pipe
20mm2
ü
Bushing (male& female)
ü
Nock- out
ü
Looping box
ü
X & Y boxes
ü
Socket -13A,15A,30A
ü
Switches-1gang -1way, 2gang
-1 way, 2gang -2 way, 3gang – 1way, 4gang -1 way and intermediate switch.
MATERIALS:
ü
Cables such as 1.5mm2,
2.5mm2 ,4mm2 ,6mm2,
10mm2 and 16mm2
TOOLS:
ü
Hacksaw
ü
Bending string
ü
Hammer
ü
Pliers
ü
Cuter
ü
Screw driver
ü
pushing tape
The formula is
KVA=KW =6.924KW
=6.924KVA. Let use 10KVA
Generator is ok.
Calculating require
Generator for the
premises or industries:
To calculate the required Generator, first of all
calculate the power rating of load assuming all the load consuming power. Let
take an example:
If there is
3 Air conditioner, 3*756=2268
Water heater
1*756=756W
13A
Socket-outlet @10, 10*1500W=15000W
Ceiling Fan
@10, 10*40W=400W
Lighting
@100, 100*200W=2000. Hence, KW=6.924KW
|
|
|

|
Hence, Cos ѳ= 0.8
INSTRUMENTS:
ü
Multi-meter for continuity test
ü
Phase meter