Repair is an action means to put in
means order or restore to a suds or at or even below their rated value and thus
reduces their rate of failure component such as capacitor which characteristics
of static field are known to have a failure rate which is approx proportional
to the 105
power of the applied voltage at fixed temperature.

CURRENT SURGE: also known as in rush current or input surge current
or switching surge is the max, instantaneous input current, or input surge
current or switch surge , is the maximum instantaneous input current drawn by
an electric device when first switch ON. These sudden fluctuations of current in excess of value contribute to component failure in
exactly the same way as voltage surge do.
Failure of electronics component:
Attention will be given to failure experience by
common electronic components, due to the operation stress, environmental stress
and manufacturing defects.
-
Fixed resistor: the commonest type of failure associate with resistor
is due to either: Open circuit, this may happens as a result of excessive heat
burning out resistor centre and
mechanical stress fracturing the resistor as in case of Carbon resistor, while
a Wire wound resistor may became open circuited due to fracture of wire
resulting from corrosion of wire due to
the electrolyzing action set u by
absorbed moisture. Mean while a film field May experience, applied voltage.


-
Intermitted contact
resulting from wearing or excessive current flow over small segment of low
resistance value.
-
Increase in résistance
value, which is very common in carbon composition resistance and is due
to the movement of carbon under the influence of heat, voltage or moisture
absorption of moisture, result in swelling or forcing of carbon particle to
separate.
-
|
|
-
-
-
Failure of capacitor may be characterized by
short/circuit which occurs due to fracture of Di-electric result 4rm shock
& vibration liking of seals.
-
Intermittent
open-circuit may be course by mechanical thermal shock and fracture of internal
fraction. Polarized
Capacitor
-
-
Transformer/ induct-or are normally characterized
by failure due to:-open-circuit in windy, short circuit of coil to the frame, over
loading, perhaps through failure of another component.
-
Semi conductors device,
failures in it are
mainly due to. Open- circuit or short cut at a junction electrical interference
failure due to the excessive temp and humility exceeding the max supply
voltage.
-
Relay: failure in a
relay may be as result of, corrosion of fine wire result in to open-circuit,
metal fatigue in armature spring. Dirty contact coursed by action of chemical
produce by sparking. Formation of dust on the relay contact which may be due to
factors external to the system or equipment such as weathers and sea water.
weather condition affect a system performance
can be categories as follows: