The above ring circuit must have 4.0mm2 as load cable.
ELECTRICAL POWER CIRCUITS
Introduction: power circuit consists of socket out let with high power
rating which include:13A,15A,20A,32A that feed power consume devices
such as Air conditioner,bathroom heater,press iron, washing machine
and warm room heater. As an electrician,there is measure to be taken for standard electrical wiring. Firstly, size of cable is very
important each power circuit has its cable rating. All power circuit must be connected independently to distribution board for safe and
accurate delivery of power supply. Only few13A socket outlets can be
tapped together, but15A and above,it must be connected to distribution
board MCB independently from 20A to above. For 13A
circuits,use 2-5mm2,15A use 4mm2 while cooker unit use 6mm2,do not loop
high power circuit is against IEE regulation. Also for piping
work,layout separate piping connection for power circuit, during the
pulling of cable you can use correct means for lubricating the high cable power rating,for easing pulling, due to long distance. There is an important precautions, as an electrician to apply,like at the natural terminals, make sure you high it accurately,also at each
socket outlet terminals make sure high it very well to avoid
electrical surges which is enemy for home appliances, so avoiding it
will safe our appliances from burning. It is advisable to assign separate distribution board for power circuit, this will give you
chance of utilizing small power rating generator for your light point.
Ring circuit must be assign to 30A MCB and load wire must be pure
copper. Ring circuit
80HP. 4HP
60KW. 30KW
https://en.m.Wikipedia. com/
must be install according to the following guidelines:
The floor area must not passed100m2,only13A socket outlet was
permitted to use in ring circuit,But 15A and above, must be install
independently Also, it advisable not connect ring circuit close to
distribution board, since closer conductor carry less impedance,which
leads to inequality share of the load. As stated earlier 2.5mm2 cable
rating is OK. It is permitted to connect spurs, that is socket outlet
attached to ring circuit, it connected using normal single cable not
like ring circuit which use double cable through each socket outlet.
Have your ever asked yourself, is their any problem or effects?
Let us look very well, if there is partially fault in ring circuit, it
will not prevent it from working. This is dangerous,because if your
Nabor house start burning without your knowledge, you too can be
affected, like wise in ring circuit if one path of cable have fault,
one day,the cable path can also affected. Do you know the risk of this
fault? The user is not aware of it. Also a result of the above mentioned problem of ring circuit, Radial
circuit is more advantageous because;if there is fault along the cable
length of the socket outlet, no more supply Until fault is rectified.
Relax ring circuit has advantage of delivering more power than radial
circuit.This can power high load safely and also this will lead to
less power loss that is voltage drop due to high diameter of cable. At
terminals of each terminal of socket out let must be high very well to
avoid surge.
Sockets are categorized under power supply in electrical wiring system. Care must be taking, concern its load wire do not under rate it. For 13A, used 2.5mm2.For 15A, use 4mm2.while for Cooker Control Unit use 6.0mm2, for safety quality power deliver
|